mos fet relays g3vm-201g1 165 mos fet relays g3vm-201g1 ultrasensitive mos fet relay in 200 v load series for power savings, sop package. ? trigger led forward current of 1 ma (maximum) facilitates power saving designs and prolonged battery life. ? continuous load current of 200 ma. ? rohs compliant application examples ? broadband systems and measurement devices ? security systems ? industrial equipment ? battery powered equipment and amusement machines note: the actual product is marked differently from the image shown here. list of models note: the ac peak and dc value are given for the load voltage. dimensions note: all units are in millimeter s unless otherwise indicated. terminal arrangement/internal connections (top view) actual mounting pad dimensions (recommended value, top view) contact form terminals load voltage (peak value) (see the note.) model number per stick number per tape spst-no surface-mounting terminals 200 v g3vm-201g1 100 --- g3vm-201g1(tr) --- 2,500 4.4 0.25 3.9 0.25 0.4 0.1 2.54 0.25 2.1 max. 0.1 0.1 7.0 0.4 0.6 0.3 0.15 g3vm-201g1 note: the actual product is marked differently from the image shown here. weight: 0.1 g omron logo model name lot no. pin 1 mark mold pin mark 43 12 43 12 g3vm-201g1 note: the actual product is marked differently from the image shown here. 6 to 6.3 1.2 0.8 2.54 g3vm-201g1
166 mos fet relays g3vm-201g1 absolute maximum ratings (t a = 25 c) electrical characteristics (t a = 25 c) recommended operating conditions use the g3vm under the following conditions so that the relay will operate properly. item symbol rating unit measurement conditions input led forward current i f 50 ma repetitive peak led forward current i fp 1 a 100 s pulses, 100 pps led forward current reduction rate i f / c ? 0.5 ma/ ct a 25 c led reverse voltage v r 5v connection temperature t j 125 c output load voltage (ac peak/dc) v off 200 v continuous load current (ac peak/dc) i o 200 ma on current reduction rate i o / c ? 2.0 ma/ ct a 25 c connection temperature t j 125 c dielectric strength between input and output (see note 1.) v i-o 1,500 v rms ac for 1 min operating temperature t a ? 40 to +85 c with no icing or condensation storage temperature t stg ? 55 to +100 c with no icing or condensation soldering temperature (10 s) --- 260 c10 s note: 1. the dielectric strength between the input and output was checked by applying voltage be- tween all pins as a group on the led side and all pins as a group on the light-receiving side. item symbol mini- mum typical maxi- mum unit measurement conditions input led forward voltage v f 1.0 1.15 1.3 v i f = 10 ma reverse current i r --- --- 10 av r = 5 v capacity between terminals c t --- 30 --- pf v = 0, f = 1 mhz trigger led forward current i ft --- 0.4 1 ma i o = 200 ma output maximum resistance with output on r on --- 5 8 i f = 2 ma, i o = 200 ma current leakage when the relay is open i leak --- 1 1000 na v off = 200 v, t a = 25 c capacity between terminals c off --- 90 --- pf v = 0, f = 1mhz capacity between i/o terminals c i-o --- 0.8 --- pf f = 1 mhz, v s = 0 v insulation resistance r i-o 1,000 --- --- m v i-o = 500 vdc, r oh 60% tu r n - o n t i m e t on --- 3 8 ms i f = 2 ma, r l = 200 , v dd = 20 v (see note 2.) turn-off time t off --- 0.6 3 ms v out i f t on t off 10% 90% i f 1 2 4 3 r l v dd v out note: 2. turn-on and turn-off times item symbol minimum typical maximum unit load voltage (ac peak/dc) v dd --- --- 160 v operating led forward current i f --- 2 25 ma continuous load current (ac peak/dc) i o --- --- 160 ma operating temperature t a ? 20 --- 65 c
mos fet relays g3vm-201g1 167 engineering data led forward current vs. ambient temperature i f - ta continuous load current vs. ambient temperature i o - ta led forward current vs. led forward voltage i f - v f led forward current i f (ma) 0 10 20 30 40 50 60 -40-200 20406080100 continuous load current i o (ma) 0 50 100 150 200 250 -40 -20 0 20 40 60 80 100 led forward current i f (ma) 0.1 1 10 100 0.8 0.9 1.0 1.1 1.2 1.3 1.4 t a = 25
ambient temperature ta (
) ambient temperature ta
led forward voltage v f (v) continuous load current vs. on-state voltage i o - v on on-state resistance vs. ambient temperature r on - ta trigger led forward current vs. ambient temperature i ft - ta continuous load current i o (ma) -250 -200 -150 -100 -50 0 50 100 150 200 250 -1.0 -0.5 0.0 0.5 1.0 0 on-state resistance r on ( ) 0 1 2 3 4 5 6 7 -40 -20 0 20 40 60 80 100 trigger led forward current i ft (ma) 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 -40 -20 0 20 40 60 80 100 0 on-state voltage v on (v ) ambient temperature ta (
) ambient temperature ta (
) turn on, turn off time vs. led forward current t on , t off - i f turn on, turn off time vs. ambient temperature t on , t off - ta current leakage vs. ambient temperature i leak - ta turn on, turn off time t on , t off (ms) 0.01 0.1 1 10 0.1 1 10 100 turn on, turn off time t on , t off (ms) 0.1 1 10 -40 -20 0 20 40 60 80 100 current leakage i leak (na) 0.001 0.01 0.1 1 10 100 -40 -20 0 20 40 60 80 100 led forward current i f (ma) ambient temperature ta (
ambient temperature ta (
) t on t off t on t off t a = 25
i f = 2ma i o = 200ma i f = 2ma t < 1s i o = 200ma t < 1s v dd = 20v r l = 200 t a = 25
v dd = 20v r l = 200 i f = 2ma v off = 200v
mos fet relays g3vm-201g1 omron on-line global - http://www.omron.com usa - http://www.components.omron.com cat. no. x302-e-1 printed in usa omron electronic components llc 55 e. commerce drive, suite b schaumburg, il 60173 847-882-2288 12/10 specificat ions subject to change without notice all sales are subject to omron electronic components llc standard terms and conditions of sale, which can be found at http://www.components.omron.com/compon ents/web/webfiles.ns f/sales_terms.html all dimensions shown are in millimeters. to convert millimeters into inches, multiply by 0.0393 7. to convert grams into ounces, multiply by 0.03527.
|